Functional, compatible and robust accessories for any pumping installation

Plugs and fittings: a full range of accessories to integrate, protect and optimize your hydraulic setup.

Float switch for FLO pumps

Filling / Emptying

20(8)A

IP68

DWC FLO float switch

Float switch suitable for the automation of water pumps and professional hydraulic systems

IP67 motor protection plug

5P

3N~400V±10%
4-6.3A

IP67

DWC PLUG 2

CEE motor protection plug (PKZM0) PI + RFC 32A 5p 6h (4.0-6.3A) IP67

layflat 2" blu

2" - 3"

4.0 bar

10.0 bar

DWC LAYFLAT

Durable, efficient and flexible (2", 3"), layflay hose is an optimal solution for rapid water discharge in case of drainage and irrigation.

dewaterco CEE extension cable 16A, 32A, 63A

10 m

16A - 32A

IP66 - IP67

DWC EXTENSION CABLE

A durable solution for industrial, civil protection and heavy-duty applications: the professional CEE extension cable is available in three versions.

Float switch for DROP pumps

Level control

10(8)

IP68

DWC DROP float switch

Submersible and reliable, the float switch features a built-in counterweight for controlling the level of drainage and wastewater.

IP67 motor protection plug

5P

3N~400V±10%
6.3-10A

IP67

DWC PLUG 3

CEE motor protection plug (PKZM0) PI + RFC 32A 5p 6h (6.3-10A) IP67

Crab Dewaterco level switch

10m

230Vac 50/60Hz 5A

IP68

DWC CRAB

Detects the presence of water on flat surfaces. Suitable for clear, rain, industrial, or chemically treated water. IP68 rated, up to 10 m deep.

IP44 motor protection plug

5P

3N~400V±10%
4-6A

IP44

DWC PLUG 1

CEE 5,5kW PI+BA+RFC 16A 5p 6h (4,0-6,0A) IP44 motor protection contactor

blue layflat 1"

1"

4.0 bar

10.0 bar

DWC LAYCAM

Strong, lightweight and flexible (1"), layflat pipe features a polypropylene quick-connect fitting for drainage, irrigation and temporary installations.

dewaterco mouse Vertical level regulator

10m

250Vac 10(8)A

IP68

DWC MOUSE

Vertical float switch for confined spaces, with 10 m cable and piggyback plug. Ideal for automatically controlling pumps up to 1.5 HP.

Dewatering pump accessories for safe and reliable installations

The right support for your effective and safe drainage system. Dewaterco Srl offers a complete line of field-tested accessories for drainage applications, including layflat hoses, plugs, hose clamps, quick couplings and much more. Every component ensures fast installation, robust connections and full compatibility with our drainage pumps.

JAKOŚĆ POPRZEZ PROJEKT

Jak powstają nasze produkty

Dewatering pump hoses, fittings and connection accessories

Components selected to ensure compatibility and reliability

Dewaterco accessories are selected and configured to properly complete every pumping system. Hoses, fittings, floats, filters, cables and connection components are evaluated according to pump compatibility, working conditions and ease of installation in the field.

Each component is carefully chosen to support the correct operation of the system. Accessory quality is essential to ensure safe connections, regular flow, easy maintenance and reliable operation during daily use or emergency situations.

Dewaterco integrates accessories within a complete system approach, rather than treating them as separate elements. This allows us to provide more organised configurations that are easy to install and technically consistent with drainage, water removal and water management requirements.

CAREFUL SELECTION

Only high quality components and materials

RIGOROUS TESTING

Każdy produkt jest sprawdzany pod kątem wydajności i niezawodności

SYSTEM INTEGRATION

Compatible with the Dewaterco ecosystem: electrical panels, pumps, accessories and kits

ZBUDOWANY, ABY PRZETRWAĆ

Solutions for demanding environments

Layflat hoses and hydraulic connections for dewatering pumps

Discharge hoses are an essential part of every drainage system because they convey the water removed by the pump towards the selected discharge point. The Dewaterco range includes lightweight, flexible and easily transportable layflat hoses suitable for temporary installations, emergency response, construction sites and professional water-transfer applications.

Rapid water discharge in mobile and temporary installations

When not in use, layflat hoses can be rolled up to minimise storage space. During operation, they expand as water flows through them, making it easier to create discharge lines over considerable distances. Selection should consider the pump outlet diameter, flow rate, operating pressure, line length and the type of connection used.

POMPA su canaletto_edited.jpg

Float switches and level sensors for automatic pump control

Level detection devices allow pump starting and stopping to be automated according to the presence or height of the water. The range includes float switches for filling and emptying, vertical level regulators for confined spaces and sensors designed to detect the presence of water even on flat surfaces.

POMPA su canaletto_edited.jpg

Water detection in tanks, sumps and flooded areas

The device should be selected according to the available space, installation type, liquid to be detected and required operating mode. Traditional float switches are suitable for tanks and sumps with sufficient room for movement, while vertical regulators and floor-level sensors can be used in more confined environments or where the water level is particularly low.

Electrical plugs and CEE extension cables for professional pumping systems

A correct electrical connection is essential for powering the pump safely and ensuring continuity during drainage operations. Dewaterco offers industrial plugs with motor protection and CEE extension cables developed for connecting pumps, electrical control panels and equipment used on construction sites, in industrial applications and during emergency response.

Reliable power supply and motor protection in the field

Plugs with motor protection help safeguard the electric pump against overload conditions, while extension cables make it possible to reach the installation point when the power source is located at a distance. Selection should be based on voltage, rated current, number of poles, motor power and the degree of protection required by the working environment.